Counting photons helped a camera tell five overlapping light sources apart
A lab test found more than a tenfold improvement in locating the sources compared with an intensity-only baseline. The team did not demonstrate sub-nanometer microscopy on a real specimen.
Reading tools for text size, copying, printing and your reading list

Five closely spaced light sources can look like a single blur to a camera. Researchers from NIST, the University of Maryland and the U.S. Naval Academy showed that a different reading of the light helps pick them apart. Instead of relying on the average brightness assigned to each pixel, they used a camera that can distinguish different numbers of arriving photons. The peer-reviewed study appeared online November 27, after the researchers released supporting data in September.[1][2][3]
In the lab, the team produced pulses from a laser and steered them onto the camera in a way that mimicked independent sources with thermal light statistics. The five sources were set up to overlap strongly and had unequal brightness. For that test, the researchers reported more than a tenfold improvement in how precisely the sources were located, compared with conventional direct imaging. Their analysis gave the intensity-only baseline the correct number of sources for the comparison. Figure 3 charts an experiment against simulated direct imaging under similar conditions; it was not a head-to-head trial on two commercial microscopes.[2]
Why the same brightness can hide different sources
An ordinary intensity image tells you how much light a pixel received on average. Two sources together can produce the same average brightness as a single brighter source. But they need not produce the same pattern of photon counts across many measurements. One might yield more readings with no photons or more bursts with several, even when the average is the same. The researchers used the spread of these counts, alongside where each pixel sits, to estimate the number, location and relative brightness of the sources.[1][2]
The distinction matters because the study is not claiming that the lens suddenly formed a perfectly sharp image. The raw signal still contained overlapping spots. The improvement came from inferring the sources behind that blur from more information than the average brightness alone provides. The team calls its method super-resolution imaging via photon enumeration.[1][2]
The approach differs from methods that sort light into spatial patterns using carefully aligned optics. Here the additional information comes from the detector’s photon counts. That makes the detector’s accuracy and the number of recorded frames part of the trade-off.[1][2]
What the camera still has to prove
The benchmark included a measurement with about 20 million detected photons as a deliberately high-statistics test, not a minimum requirement. Noise in the commercial camera reduced the gain relative to the simulations, and pooling data from nearby pixels helped counter some detector distortions in the two-dimensional reconstruction. The reported factor describes this proof of principle, not a universal upgrade for any camera or subject.[2][3]
The paper’s sub-nanometer localization prediction comes from simulations for fluorescent emitters, not from a microscope imaging a real fluorescent sample. A practical next test would be to see how well the method holds up with dimmer sources and a shorter acquisition. The authors report that two members of the team are named as inventors on a pending U.S. patent application covering the method.[1][2]