Two quantum tests have the same margin. One needs more copies as it grows.
A new proof shows why testing a quantum state at 99% versus 98% fidelity can require fewer copies than testing it at 96% versus 95%, when the qubits must be measured one at a time.
Reading tools for text size, copying, printing and your reading list

Suppose a lab has to check whether it made the quantum state it intended. In one test, it must accept preparations that score at least 99% and reject those that score 98% or less. In another, the cutoffs are 96% and 95%. Both tests separate their thresholds by one percentage point. Yet for the class of states considered in a new proof, the first can use a number of copies that stays constant as the system grows. A copy is a fresh run of the same preparation. The second can require a number that grows in proportion to the number of .[1]
Yimeng Cao and Ge Bai at the Hong Kong University of Science and Technology in Guangzhou asked what a lab can learn when each qubit has to be measured separately. The lab can combine the readings afterward, but it can’t perform a single measurement across the whole system. This makes hardware control simpler and avoids having to reconstruct the entire state. The cost is that a test may need more repeats of the preparation to make a reliable decision.[1]
The gap that matters is relative
The percentages refer to fidelity, a measure of how closely the prepared state matches the intended one. The test promises to accept sufficiently good states and reject sufficiently bad ones with high probability. It makes no promise for states between the two cutoffs.[1]
The key is to compare that one-point gap with how far the rejection cutoff sits below a perfect match. At 98%, the rejected state is two points below perfect. The one-point gap is half of that. At 95%, there are five points to perfect, so the same gap is just one-fifth. In the authors’ analysis, those two ratios land on opposite sides of a boundary: the former allows a constant number of copies at a fixed confidence level, while the latter needs a number that grows linearly with system size. Tighten the relative gap further and the required power of system size rises in steps.[1]
What this tells a lab, and what it doesn’t
The proof concerns known pure target states that are typical in a mathematical sense: as the number of qubits grows, the result applies to an increasing fraction of all randomly drawn pure targets. It doesn’t say that every state a lab cares about behaves this way, or specify a fixed number of copies to buy or prepare. It describes how the best possible test scales, not a hardware result. The authors published a computer-checked version of the main mathematical results.[1][2]
For labs using separate measurements, the point is to set the two cutoffs before budgeting the runs. For labs that can measure small groups jointly, the authors show that the answer can change again. Holding the measurement setup and desired confidence fixed is what makes a comparison of copy counts useful.[1]