Skip to content
EVIDENCE RECORD

IQM Quantum Computers: what changed.

The recorded research and its supporting evidence.

This is a historical record. Read the current company research →
  1. 2 evidence sources added · axis ratings unchanged

    Assessment reviewed 24 Nov 2026 · Research reviewed 24 Nov 2026
    What changed
    Capability rationale
    Previously

    External circuit experiments and calibration analysis characterize an operating QPU, including performance variation across qubits and time.

    Now

    Q-Exa calibration and GHZ use characterize an operating 20-qubit processor. The Q50 guide documents physical operations on a separate system.

    Delivery rationale
    Previously

    Maintained client documentation and a customer-operated Q50 access service establish supported hardware offerings and operational resources.

    Now

    IQM Resonance and VTT QX provide documented access paths. VTT supplies device-specific modes and access arrangements.

    Use in practice rationale
    Previously

    External researchers used Q-Exa, and VTT reports Q50 use in a live gaming demonstration. These are documented research and demonstration uses.

    Now

    The Q-Exa calibration study and VTT demonstration give identifiable external and development-partner use. General performance claims require broader evidence.

    Integration rationale
    Previously

    IQM maintains reusable circuit/pulse tooling, authentication, calibration and result workflows; VTT also reports implementing an application interface.

    Now

    IQM and VTT publish credential, calibration and operations resources, with native gates and limits on supported feedback.

    Summary
    Previously

    IQM combines installed superconducting systems with Resonance cloud access and documented developer tools. External evidence includes extended Q-Exa calibration analysis and live VTT Q50 use.

    Now

    IQM offers superconducting systems through Resonance and installed partners. Independent Q-Exa research characterizes calibration variability. VTT offers its installed Q50 through QX and documents native operations.

    Current access
    Previously

    Cloud and installed systems: IQM’s client guide explains Resonance account access and backend calibration. VTT also offers its installed Q50 through QX; access terms depend on the provider.

    Now

    Cloud and installed systems: IQM’s client guide covers credentialed Resonance access and calibration selection. VTT offers its installed Q50 through QX and documents native gates and hardware-dependent feedback groups.

    Retained for this claim (1)
    What the research demonstrates
    Previously

    External researchers studied 250 days of Q-Exa operation and validated circuit performance. VTT separately reports real-time Q50 execution for a gaming demonstration.

    Now

    External researchers analyzed more than 250 days of 20-qubit Q-Exa calibration data and tested their model with GHZ circuits. VTT separately reports Q50 use for real-time game-level generation.

    Added to this claim (1)
    Removed from this claim (1)
    Retained for this claim (1)
    Evidence sources
    Added to this claim (1)
    Research evidence: Qiskit on IQM User Guide
    Where to look

    Calibration-set selection; Inspecting results → Authentication; calibration-set selection; classically controlled gates

    Source checked

    2026-11-12 → 2026-11-24

    Source or product version

    IQM client 36.0.0 living guide checked 12 November → IQM client 37.0.0 living guide

    Compare both full records

    Previously

    Documents Resonance authentication, circuit submission, calibration-set selection, job results and limitations on classically controlled gates. Resources include maintained client adapters and examples.

    Source title
    Qiskit on IQM User Guide
    Source publication date
    Not recorded
    Source type
    technical
    Marked independent
    Not recorded
    Where to look
    Calibration-set selection; Inspecting results
    Source checked
    12 Nov 2026
    Source or product version
    IQM client 36.0.0 living guide checked 12 November
    Limitations
    A created backend retains its original default calibration; result metadata records the chosen set.

    Now

    Documents Resonance authentication, circuit submission, calibration-set selection, job results and limitations on classically controlled gates. Resources include maintained client adapters and examples.

    Source title
    Qiskit on IQM User Guide
    Source publication date
    Not recorded
    Source type
    technical
    Marked independent
    Not recorded
    Where to look
    Authentication; calibration-set selection; classically controlled gates
    Source checked
    24 Nov 2026
    Source or product version
    IQM client 37.0.0 living guide
    Limitations
    A created backend retains its original default calibration; result metadata records the chosen set.
    Delivery evidence mapping
    Added to this claim (1)
    Removed from this claim (1)
    Retained for this claim (2)
    Integration evidence mapping
    Added to this claim (1)
    Removed from this claim (1)
    Retained for this claim (2)
    Sources used in this record (7)

Recorded dates use UTC and show when QubitWire saved the comparison. Review dates show the evidence check; neither is a new claim about when the underlying event happened. This view preserves the original research and assessment methodology.