Why a qubit’s lifetime can change even when the chip stays the same
In a new AWS experiment, one superconducting qubit looked remarkably different depending on where researchers measured it. Sweeping across frequencies made the same hardware easier to judge.
Reading tools for text size, copying, printing and your reading list

Ask how long a can hold energy and you might expect one number. In a new preprint from the AWS Center for Quantum Computing, the same qubit had a measured relaxation time near 100 microseconds across much of its tuning range but fell to around one microsecond in the deepest dips. The team’s result is not a longer-lived qubit. It is a way to tell whether differences between measurements reflect the chip or the conditions of the test.[1]
Why the number moves
Energy relaxation time, often written as T1, describes how quickly a qubit loses energy after being put into its higher-energy state. AWS used a superconducting design called a transmon whose operating frequency can be adjusted with a magnetic field. At some frequencies, the qubit can exchange energy with microscopic defects in and around the materials of the circuit. That can produce deep dips in the measured lifetime. The frequencies of those dips can change with time or after the chip is warmed and cooled again.[1]
The researchers measured relaxation over a range of about 2.7 gigahertz. They converted each measurement to a quality factor, a number that accounts for frequency: at the same lifetime, a higher-frequency qubit completes more oscillations before its energy decays. They kept the distribution of those values rather than selecting a peak or reducing everything to a single average. That gave them a way to see how frequently poor readings occurred even when the lowest points moved.[1]
Three ways to measure the same qubit
Over three days the team compared repeated measurements at one frequency, sweeps across 50 megahertz and sweeps across the wider 2.7-gigahertz band. The tests used the same measurement time and 3,000 points each. Across eight repeats, the median quality factors spread by 74% at one frequency, 37% across the narrow band and 6% across the broad band. Those percentages describe how much the readings varied between tests, not an improvement in the qubit’s lifetime.[1]
The team also compared 17 broad sweeps across four temperature cycles over 326 days. The first three cycles had similar distributions. The fourth, measured in a different refrigerator, had higher quality factors and lacked the deepest broad dips seen earlier. This is an important limit: a wider test was more repeatable, but it did not make the defects disappear or guarantee the same result after every cooldown. In a second comparison, the team measured three identically designed qubits on each of two chips cut from the same wafer. It could see small differences, but the sample was not a survey of an entire production line.[1]
What to ask when you see a lifetime record
A best-case lifetime can show what a device achieved at an especially favorable operating point. To judge fabrication, ask how the device performed across frequencies and whether that pattern held on another day or after another cooldown. Engineers still need to check specific operating frequencies and run actual gates. This preprint reports neither a reduced gate error rate nor an improvement in . Its contribution is a fairer way to tell when a better reading might mean a better chip.[1]